Sega BG-SSC-004 Manuel d'utilisateur Page 16

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 33
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 15
16
sensing.honeywell.com
Specifications
±0.5 inH
2
O to ±150 psi
Table 10. Pressure Range Specifications for 0.5 inH
2
O to 150 psi
Pressure
Range
(see
Figure 4)
Pressure
Range
Unit
Working
Pressure
1
Over
Pressure
2
Burst
Pressure
3
Common
Mode
Pressure
4
Total Error
Band
5
(%FSS)
Total Error
Band after
Auto-Zero
6
(%FSS)
Long-term
Stability
1000 hr, 25 °C
(%FSS)
Pmin.
Pmax.
Absolute
015PA 0 15 psi - 30 60 - ±2% - ±0.25%
030PA 0 30 psi - 60 120 - ±2% - ±0.25%
060PA 0 60 psi - 120 240 - ±2% - ±0.25%
100PA 0 100 psi - 250 250 - ±2% - ±0.25%
150PA 0 150 psi - 250 250 - ±2% - ±0.25%
Differential
0.5ND -0.5 0.5 inH
2
O 135 270 415 1400 ±4% ±3% ±0.5%
001ND -1 1 inH
2
O 135 270 415 1400 ±3% ±1.5% ±0.35%
002ND -2 2 inH
2
O 135 270 415 1400 ±2% ±1% ±0.35%
004ND -4 4 inH
2
O 150 300 500 2200 ±2% ±0.75% ±0.25%
005ND -5 5 inH
2
O 150 300 500 2200 ±2% ±0.75% ±0.25%
010ND -10 10 inH
2
O 175 350 550 4200 ±2% ±0.75% ±0.25%
020ND -20 20 inH
2
O 175 350 550 4200 ±2% ±0.75% ±0.25%
030ND -30 30 inH
2
O 175 350 550 4200 ±2% ±0.75% ±0.25%
001PD -1 1 psi - 10 15 150 ±2% - ±0.25%
005PD -5 5 psi - 30 40 150 ±2% - ±0.25%
015PD -15 15 psi - 60 120 150 ±2% - ±0.25%
030PD -30 30 psi - 120 240 150 ±2% - ±0.25%
060PD -60 60 psi - 250 250 250 ±2% - ±0.25%
Gage
001NG 0 1 inH
2
O
135 270 415 1400
±4% ±3%
±0.5%
002NG 0 2 inH
2
O 135 270 415 1400 ±3% ±1.5% ±0.35%
004NG 0 4 inH
2
O 135 270 415 1400 ±2% ±1% ±0.35%
005NG 0 5 inH
2
O 135 270 415 1400 ±2% ±1% ±0.25%
010NG 0 10 inH
2
O 150 300 500 2200 ±2% ±0.75% ±0.25%
020NG 0 20 inH
2
O 175 350 550 4200 ±2% ±0.75% ±0.25%
030NG 0 30 inH
2
O 175 350 550 4200 ±2% ±0.75% ±0.25%
001PG 0 1 psi - 10 15 150 ±2% - ±0.25%
005PG 0 5 psi - 30 40 150 ±2% - ±0.25%
015PG 0 15 psi - 30 60 150 ±2% - ±0.25%
030PG 0 30 psi - 60 120 150 ±2% - ±0.25%
060PG 0 60 psi - 120 240 250 ±2% - ±0.25%
100PG 0 100 psi - 250 250 250 ±2% - ±0.25%
150PG 0 150 psi - 250 250 250 ±2% - ±0.25%
1
Working pressure: The maximum pressure that may be applied to any port of the sensor in continuous use. This pressure may be outside the operating pressure range limits (Pmin. to
Pmax.) in which case the sensor may not provide a valid output until pressure is returned to within the operating pressure range. Tested to 1 million cycles, minimum.
2
Overpressure: The maximum pressure which may safely be applied to the product for it to remain in specification once pressure is returned to the operating pressure range. Exposure
to higher pressures may cause permanent damage to the product. Unless otherwise specified this applies to all available pressure ports at any temperature with the operating
temperature range.
3
Burst pressure: The maximum pressure that may be applied to any port of the product without causing escape of pressure media. Product should not be expected to function after
exposure to any pressure beyond the burst pressure.
4
Common mode pressure: The maximum pressure that can be applied simultaneously to both ports of a differential pressure sensor without causing changes in specified
performance.
5
Total Error Band: The maximum deviation from the ideal transfer function over the entire compensated temperature and pressure range. Includes all errors due to offset, full scale
span, pressure non-linearity, pressure hysteresis, repeatability, thermal effect on offset, thermal effect on span, and thermal hysteresis
6
Total Error Band after Auto-Zero: The maximum deviation from the ideal transfer function over the entire compensated pressure range at a constant temperature and supply voltage
for a minimum of 24 hours after an auto-zero operation. Includes all errors due to full scale span, pressure non-linearity, pressure hysteresis, and thermal effect on span.